5.1.2.1.3. Non-Functional Requirements

Requirement: TimingConstraint REQ_INT3_1732140084 ../../../../../_images/arrow-right-circle.svg
status: Draft
style: red_bar
category: Non-Functional
priority: Low

The clock initialization process must complete within 2 milliseconds.

Requirement: InterferenceMinimization REQ_INT3_1732217665 ../../../../../_images/arrow-right-circle.svg
status: Draft
style: red_bar
category: Non-Functional
priority: Low

The clock initialization must not disrupt ongoing peripheral operations.

Requirement: SwitchToHSIOnFailure REQ_INT3_1732217305 ../../../../../_images/arrow-right-circle.svg
status: Draft
style: red_bar
category: Non-Functional
priority: Low

In case of oscillator failure, the system must switch to HSI as the clock source.

Requirement: NotifyUserOnFailure REQ_INT3_1732217396 ../../../../../_images/arrow-right-circle.svg
status: Draft
style: red_bar
category: Non-Functional
priority: Low

The system must notify the user of an oscillator failure through status bits.